Double-Low technique: The optimal protocol for Chest CT, Abdomen CT, CT Coronary Angiography and CT Pulmonary Angiography
Abstract
The main goal in radiology is to obtain high quality images with the least radiation dose to the patient. In order to be achieved diagnostically acceptable Computed Tomography (CT) images with a minimum dose of radiation and contrast media (CM) many approaches have been developed. “Double-Low” technique is an encouraging approach which refers to the combination of low tube voltage and low CM load using an iterative reconstruction algorithm (IR). The purpose of this study is to compare the most recently proposed approaches on “double-low” technique to the standard protocols and determine the optimum protocol for each anatomical region. Regarding the abdominal CT a reduction in the CTDIvol and CM load of up to 20-30% and 22.9-40% respectively was reported. While, as for the chest CT a reduction in the effective and CM dose of up to 25-32% and 23-30% respectively was revealed. Moreover, in the CT Coronary Angiography (CTCA) the results showed a reduction of the effective and CM dose of up to 13.5-94.8% and 20-60.7% respectively. Finally, with respect to the CT Pulmonary Angiography (CTPA) a reduction of the effective and CM dose of up to 27-63.6% and 22.9-58.3% respectively was mentioned.
Keywords
Full Text:
PDFReferences
Aschoff A J, Catalano C, Kirchin M A, et al. Low radiation dose in computed tomography: the role of iodine. Br J Radiol. 2017; doi:10.1259/bjr.20170079. Epub 2017 May 4.
Andersson J, Pavlicek W, Al-Senan R, et al. Estimating Patient Organ Dose with Computed Tomography: A Review of Present Methodology and Required DICOM Information A Joint Report of AAPM Task Group 246 and the European Federation of Organizations for Medical Physics (EFOMP). AAPM Report No. 246 2019; doi:10.37206/190. Epub 2019 August 1.
Sahbaee P, Segars W P, Marin D, et al. The Effect of Contrast Material on Radiation Dose at CT: Part I. Radiology 2017; doi:10.1148/radiol.2016152851. Epub 2017 Jan 13.
Sahbaee P, Abadi E, Segars W P, et al. The Effect of Contrast Material on Radiation Dose at CT: Part II. A Systematic Evaluation across 58 Patient Models. Radiology 2017; doi:10.1148/radiol.2017152852. Epub 2017 Mar 13.
Amato E, Salamone I, Naso S, et al. Can Contrast Media Increase Organ Doses in CT Examinations? A Clinical Study. AJR Am J Roentgenol. 2013; doi:10.2214/AJR.12.8958. Epub 2013 Jun.
Nagayama Y, Tanoue S, Tsuji A, et al. Application of 80-kVp scan and raw data-based iterative reconstruction for reduced iodine load abdominal-pelvic CT in patients at risk of contrast-induced nephropathy referred for oncological assessment: effects on radiation dose, image quality and renal function. Br J Radiol. 2018; doi: 10.1259/bjr.20170632. Epub 2018 Mar 2.
Meng D, Cui X, Bai C, et al. Application of low-concentration contrast agents and low-tube-voltage computed tomography to chest enhancement examinations: A multicenter prospective study, SciProg. 2020; doi: 10.1177/0036850419892193. Epub 2019 Dec 2.
Cha M J, Kim S M, Ahn T R, et al. Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography. PLoS ONE 2020; doi: 10.1371/journal.pone.0236108. Epub 2020 July 16.
Seyal A R, Arslanoglu A, Abboud S F, et al. CT of the Abdomen with Reduced Tube Voltage in Adults: A Practical Approach. Radiographics 2015; doi: 10.1148/rg.2015150048. Epub 2015 Oct 16.
Van Hamersvelt R W, Eijsvoogel N G, Mihl C, et al. Contrast agent concentration optimization in CTA using low tube voltage and dual-energy CT in multiple vendors: a phantom study. Int J Cardiovasc Imaging 2018; doi: 10.1007/s10554-018-1329-x. Epub 2018 Mar 8.
Mazloumi M, Van Gompel G, Kersemans V, et al. The presence of contrast agent increases organ radiation dose in contrast-enhanced CT. EurRadiol. 2021; doi: 10.1007/s00330-021-07763-7. Epub 2021 Mar 30.
Sakabe D, Nakaura T, Oda S, et al. Decreasing the radiation dose for contrast-enhanced abdominal spectral CT with a half contrast dose: a matched-pair comparison with a 120 kVp protocol. BJR Open 2020; doi: 10.1259/bjro.20200006. Epub 2020 Dec 11.
Miyoshi K, Onoda H, Tanabe M, et al. Image quality in dual-source multiphasic dynamic computed tomography of the abdomen: evaluating the effects of a low tube voltage (70 kVp) in combination with contrast dose reduction. Abdom Radiol (NY) 2020; doi: 10.1007/s00261-020-02565-9. Epub 2020 May 7.
Svensson A, Thor D, Fischer MA, et al. Dual source abdominal computed tomography: the effect of reduced X-ray tube voltage and intravenous contrast media dosage in patients with reduced renal function. Acta Radiol 2019; doi: 10.1177/0284185118783213. Epub 2018 Jun 22.
Hanson G J, Michalak G J, Childs R, et al. Low kV versus dual-energy virtual monoenergetic CT imaging for proven liver lesions: what are the advantages and trade-offs in conspicuity and image quality? A pilot study. Abdom Radiol (NY). 2018; doi:10.1007/s00261-017-1327-9. Epub 2018 Jun 1.
Kim S Y, Cho J Y, Lee J, et al. Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial for Comparison with Conventional CT Urography. Korean J Radiology 2018; doi: 10.3348/kjr.2018.19.6.1119. Epub 2018 Oct 18.
Feng C, Zhu D, Zou X, et al. The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography: Effects on image quality and radiation dose. Medicine (Baltimore) 2018; doi:10.1097/MD.0000000000010151. Epub 2018 Mar 23.
Eller A, Wuest W, Saake M, et al. Extent of simultaneous radiation dose and iodine reduction at stable image quality in computed tomography of the chest: A systematic approach using automated tube voltage adaption and iterative reconstructions. Medicine (Baltimore) 2018; doi: 10.1097/MD.0000000000010388. Epub 2018 Apr 13.
Solbak M S, Henning M K, England A, et al. Impact of iodine concentration and scan parameters on image quality, contrast enhancement and radiation dose in thoracic CT. European Radiology Experimental 2020; doi: 10.1186/s41747-020-00184-z. Epub 2020 Sep 11.
Hoshika M, Nakaura T, Oda S, et al. Comparison of the effects of varying tube voltage and iodinated concentration on increasing the iodinated radiation dose in computed tomography. Phys Med. 2022; doi: 10.1016/j.ejmp.2022.01.007. Epub 2022 Jan 29.
Zhang H, Ma Y, Lyu J, et al. Low kV and Low Concentration Contrast Agent with Iterative Reconstruction of Computed Tomography (CT) Coronary Angiography: A Preliminary Study. Med Sci Monit 2017; doi: 10.12659/msm.904251. Epub 2017 Oct 20.
Oda S, Takaoka H, Katahira K, et al. Low contrast material dose coronary computed tomographic angiography using a dual-layer spectral detector system in patients at risk for contrast-induced nephropathy. Br J Radiol 2019; doi: 10.1259/bjr.20180215. Epub 2018 Nov 14.
Feng R, Tong J, Liu X, et al. High-Pitch Coronary CT Angiography at 70 kVp Adopting a Protocol of Low Injection Speed and Low Volume of Contrast Medium. Korean J Radiol 2017; doi:10.3348/kjr.2017.18.5.763. Epub 2017 Jul 17.
Jia C F, Zhong J, Meng X Y, et al. Image quality and diagnostic value of ultra low-voltage, ultra low-contrast coronary CT angiography. Eur Radiol 2019; doi: 10.1007/s00330-019-06111-0. Epub 2019 Mar 19.
Zhao L, Bao J, Guo Y, et al. Ultra-low dose one-step CT angiography for coronary, carotid and cerebral arteries using 128-slice dual-source CT: A feasibility study. ExpTher Med 2019; doi: 10.3892/etm.2019.7420. Epub 2019 Mar 20.
Huang X, Gao S, Ma Y, et al. The optimal monoenergetic spectral image level of coronary computed tomography (CT) angiography on a dual-layer spectral detector CT with half-dose contrast media. Quant Imaging Med Surg. 2020; doi: 10.21037/qims.2020.02.17. Epub 2020 Mar.
Hu X, Ma L, Zhang J, et al. Use of pulmonary CT angiography with low tube voltage and low-iodine-concentration contrast agent to diagnose pulmonary embolism. Sci Rep. 2017; doi: 10.1038/s41598-017-13077-w. Epub 2017 Oct 16.
Suntharalingam S, Mikat C, Stenzel E, et al. Submillisievert standard-pitch CT pulmonary angiography with ultra-low dose contrast media administration: A comparison to standard CT imaging. PLoS One. 2017; doi:10.1371/journal.pone.0186694. Epub 2017 Oct 18.
Aldosari S, Al-Mantshari A, AlQahtani T, et al. Double low-dose computed tomography pulmonary angiography in the diagnosis of pulmonary embolism. J. Phys.: Conf. Ser. 2019; doi:10.1088/1742-6596/1248/1/012032. Epub 2019.
Aldosari S and Sun Z. A Systematic Review of Double Low-dose CT Pulmonary Angiography in Pulmonary Embolism. Curr Med Imaging Rev. 2019; doi: 10.2174/1573405614666180813120619. Epub 2019 May 31.
DOI: http://dx.doi.org/10.36162/hjr.v8i1.516
Refbacks
- There are currently no refbacks.